Please use this identifier to cite or link to this item: http://repository.eia.edu.co/handle/11190/1979
Title: Sistema de electroestimulación y electromiografía para hospitalización
Authors: Mejía Jaramillo, María Clara
Adviser: Quintana Gómez, Laura Melissa
Keywords : Rehabilitación
Electromiografía
Electroestimulación
Hospitalización
Rehabilitation
Hospitalization
Electromyography
Electrical muscle stimulation
Issue Date: 2017
Publisher: Universidad EIA
Abstract: Una hospitalización prolongada, sin importar la razón por la que esta ocurra, puede conllevar a efectos adversos, en los diferentes sistemas encargados del movimiento corporal humano, esto se da principalmente debido a que los pacientes deben estar constantemente en una cama y entre mayor sea este tiempo, los sistemas se verán más comprometidos (Sánchez Rojas, 2011). Debido al síndrome de desacondicionamiento físico y todas las consecuencias que este trae se plantea la siguiente pregunta ¿Cómo se puede evitar o mejorar el desacondicionamiento físico en pacientes hospitalizados? En la etapa de diseño conceptual se han obtenido los parámetros básicos de diseño y criterios de selección de concepto mediante una búsqueda bibliográfica y entrevistas con especialistas. Una vez seleccionado el concepto, se desarrolló el diseño a detalle, logrando superar los objetivos planteados en un principio. Dicho diseño, se realizó bajo los criterios obtenidos en el desarrollo metodológico, terapias pasivas y activo-pasivas, bioinstrumentación, electrónica, con el soporte de herramientas CAD y programación. Lo cual permitió establecer los componentes y materiales para cada subsistema del sistema de rehabilitación. Como producto final se obtuvo un sistema que permite la rehabilitación activa y pasiva de un paciente en hospitalización en diferentes posiciones debido a las diferentes graduaciones, que además permite que esta sea monitoreada remotamente por medio de EMG.
Abstract (English): A prolonged hospitalization, no matter the reason why this occur, can have adverse effects in the musculoskeletal system, the principal cause for it is the long stay in the hospitalization beds, the longer time the person spends in the bed, the worst is the damage to the system (Sánchez Rojas, 2011). Due to the physical deconditioning and all its consequences, the next question was formulated. How can be avoided or improved the physical deconditioning? In the conceptual design phase, the basic parameters were defined and the concept selection criteria, it was made by a bibliographic research and interviews with professionals. Once the selection was made, the detail design was completed. This project goes beyond the specifics aims. The design was developed under the methodologic phase criteria. Active and passive therapy, bioinstrumentation, electronics, and programing and CAD design software. This allowed to establish the materials to every subsystem of the device. The final product was a device for the active and passive therapy of a patient in a lot of positions due to the graduations of the system. The device also allows the remote monitoring by EMG.
Description: 119 páginas
URI: http://repository.eia.edu.co/handle/11190/1979
Citation: Mejía Jaramillo, M.C. (2017) Sistema de electroestimulación y electromiografía para hospitalización (Trabajo de grado). Recuperado de: http://repository.eia.edu.co/handle/11190/1979
Autorization: openAccess
Location: BIOM/0276
Appears in Collections:Ingeniería Biomédica