Please use this identifier to cite or link to this item: http://repository.eia.edu.co/handle/11190/2244
Title: Dispositivo portátil para el análisis de la variabilidad de la frecuencia cardíaca en tiempo real
Authors: Chanci Arrubla, Daniela
Adviser: Mejía Mejía, Elisa
Keywords : Epilepsia
Variabilidad de la frecuencia cardíaca
Biomarcador
Dispositivo portátil
Epilepsy
Heart rate variability
Biomarker
Wearable device
Issue Date: 2018
Publisher: Universidad EIA
Abstract: La variabilidad de la frecuencia cardíaca es una variable fisiológica que ha llamado la atención de los investigadores en los últimos años, ya que puede ser utilizada para monitorizar el sistema nervioso autónomo y está relacionada con diferentes enfermedades crónicas, como la epilepsia, que es uno de los trastornos neurológicos más comunes en el que se presentan crisis convulsivas que pueden causar lesiones y accidentes. Debido a esto, se han realizado estudios para utilizar esta variable como biomarcador para la predicción de crisis epilépticas. Este trabajo presenta el desarrollo de un dispositivo portátil para el análisis de la variabilidad de la frecuencia cardíaca en tiempo real, que incluye medidas en tiempo y no lineales. Inicialmente, se realizó una revisión bibliográfica para seleccionar la estrategia óptima para la obtención de la variabilidad de la frecuencia cardíaca y la parte del cuerpo más adecuada para la ubicación del dispositivo. Luego se construyó el circuito electrónico, realizando las pruebas de funcionamiento correspondientes para proceder a la elaboración del circuito impreso, y se desarrolló el firmware necesario para el análisis de la variable fisiológica en tiempo real. Finalmente, se construyó el componente externo y se realizaron las pruebas de funcionamiento del dispositivo final.
Abstract (English): Heart rate variability is a physiological variable that has caught the researchers’ attention over the past few years, because it can be used for monitoring the autonomic nervous system and it is associated with many chronic diseases, for example, epilepsy, which is one of the most common neurological disorders that manifests itself as seizures that can cause injuries and accidents. This is the reason why some studies have been conducted in order to use this variable as a biomarker for epileptic seizures prediction. This work presents the development of a wearable device for real time heart rate variability analysis, which includes time and non linear measures. Firstly, a literature review was done in order to select the best strategy for the acquisition of heart rate variability and the most suitable part of the body for putting the device. Then, the electronic circuit was built, conducting the corresponding performance tests to proceed with the development of the printed circuit, and the firmware needed for the real time physiological variable analysis was made. Lastly, the external component was manufactured and the performance tests of the final device were conducted.
Description: 77 páginas
URI: http://repository.eia.edu.co/handle/11190/2244
Citation: Chanci Arrubla, D. (2018). Dispositivo portátil para el análisis de la variabilidad de la frecuencia cardíaca en tiempo real (Trabajo de grado). Recuperado de: http://repository.eia.edu.co/handle/11190/2244
Location: BIOM0301
Appears in Collections:Ingeniería Biomédica

Files in This Item:
File Description SizeFormat 
ChanciDaniela_2018_DispositivoPortatilAnalisis.pdfTrabajo de grado1.89 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.