Please use this identifier to cite or link to this item: http://repository.eia.edu.co/handle/11190/2134
Title: Magnetic properties map of a CoFe and NiFe multi-layer compound with a Ruthenium spacer wedge
Authors: Builes, Juan Felipe
Keywords : X-ray
Magnetism
Circular dichroism
Hysteresis-loop
Spectroscopy
Graphical User Interface
Rayos X
Magnetismo
Dicroísmo circular
Bucle de histéresis
Espectroscopia
Interfaz gráfica de usuario
Issue Date: 2015
Publisher: Universidad EIA
Abstract: Este proyecto se centra en el mapeo magnético con rayos X blandos, tenía dos componentes: una parte experimental y una parte técnica. La parte experimental midió la espectroscopia de absorción de rayos X, el dicroísmo circular magnético de rayos X y el bucle de histéresis magnética en el Beamline 6.3.1 en una muestra de dos capas magnéticas, separadas por una cuña de rutenio de 3.1 nm de espesor. Usando rayos X, uno investigó cómo la interacción magnética entre los dos depende significativamente del grosor del separador de rutenio. Se observó una alta influencia de las propiedades magnéticas de las capas y del grosor del espaciador de rutenio. La parte técnica consistió en desarrollar una aplicación de Interfaz Gráfica de Usuario (GUI) en Python para generar los archivos de entrada para experimentos automatizados en Beamline. Convencionalmente, solo se midieron unos pocos espectros de absorción a la vez. Con la nueva aplicación, es fácil de usar ejecutar cientos de escaneos seguidos, permitiendo a los usuarios hacer un mejor uso de las capacidades de Beamline.
Abstract (English): This project is centered on magnetic mapping with soft x-rays, it had two components: an experimental part and a technical part. The experimental part was measuring x-ray absorption spectroscopy, x-ray magnetic circular dichroism, and magnetic hysteresis loop at the Beamline 6.3.1 on a sample of two magnetic layers, separated by a 3.1nm thin Ruthenium wedge. Using x-rays, one investigated how the magnetic interaction between the two significantly depends on the thickness of the Ruthenium separator. It was observed a high influence of the magnetic properties of the layers and the Ruthenium spacer thickness. The technical part consisted in developing a Graphical User Interface (GUI) application in Python to generate the input files for automated experiments at the Beamline. Conventionally, only a few absorption spectra were measured at a time. With the new application, it is user friendly to run hundreds of scans in a row, allowing the users to make better use of the Beamline's capabilities.
Description: 22 páginas
URI: http://repository.eia.edu.co/handle/11190/2134
Citation: Builes Villegas, J.F. (2015). Magnetic properties map of a CoFe and NiFe multi-layer compound with a Ruthenium spacer wedge (Trabajo de grado). Recuperado de: http://repository.eia.edu.co/handle/11190/2134
Location: INDU00239
Appears in Collections:Ingeniería Industrial

Files in This Item:
File Description SizeFormat 
BuilesJuan_2015_MagneticPropertiesMAp.pdfTrabajo de grado1.87 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.