Please use this identifier to cite or link to this item: http://repository.eia.edu.co/handle/11190/1973
Title: Sistema para la monitorización de la presión intraabdominal
Authors: Gómez González, Juan Manuel
Mejía Mejía, Elisa
Adviser: Torres Villa, Róbinson Alberto
Keywords : Presión intraabdominal
Síndrome compartimental abdominal
Pared abdominal
Fotopletismografía
Pulsoximetría
Intraabdominal pressure
Abdominal compartment syndrome
Abdominal wall
Photoplethysmography
Pulse oximetry
Issue Date: 2014
Publisher: Universidad EIA
Abstract: El aumento de la presión intraabdominal (PIA) por encima de ciertos límites puede llevar al desarrollo de una condición potencialmente mortal conocida como el síndrome compartimental abdominal (SCA). Actualmente, la medición de la PIA se hace por medio de diferentes técnicas, siendo casi todas ellas invasivas y que pueden llevar a otras complicaciones o medidas falsas, especialmente en algunas poblaciones de pacientes, como niños o personas obesas. Una alta PIA tiene efectos fisiológicos sobre virtualmente todos los órganos mayores, como el corazón, los pulmones y el cerebro, afectando sus funciones normales y sus propias presiones. Entre estos efectos se ha encontrado la disminución del riego sanguíneo en el abdomen, generando que la oxigenación abdominal baje. Algunos estudios han mostrado una relación inversa entre el aumento de la PIA y el decremento de la saturación de oxígeno en el tejido abdominal usando la técnica de espectroscopia del infrarrojo cercano. Otra técnica óptica, la pulsoximetría, podría permitir la determinación de esta relación. Esta técnica utiliza la señal fotopletismográfica para estimar la saturación de oxígeno arterial usando un indicador conocido como SpO2. Las bases de la pulsoximetría, el diseño y construcción de un sensor de pulsoximetría por reflexión y el diseño, construcción y caracterización de un sistema de instrumentación para la medición de la saturación de oxígeno en la pared abdominal se describen y analizan en este trabajo.
Abstract (English): The increase of the intra-abdominal pressure (IAP) above some limits may lead to the development of a potentially mortal condition, the abdominal compartment syndrome (ACS). Several approaches are used nowadays for measuring the IAP but most of them are invasive and may lead to other complications or false measurements, especially in high risk populations as children or obese people. The increased IAP has physiological effects on virtually all major organs, as the heart, the lungs and the brain, affecting their normal functions and pressures. Among these effects is the decrease of abdominal flow leading to the decrease of abdominal oxygenation. Some studies have shown an inverse relationship between the increase of IAP and the decrease of oxygen saturation in the abdominal tissue using the near-infrared spectroscopy technique. Another optical technique, pulse oximetry, could be able to determine this relationship. This technique uses the photoplethysmographic signal to estimate the arterial blood oxygen saturation using an indicator known as SpO2. The basics of pulse oximetry, the design and construction of a reflectance pulse oximetry sensor and the design, construction and characterization of an instrumentation system for the oxygen saturation measurement in the abdominal wall are described and analyzed in this study.
Description: 136 páginas
URI: http://repository.eia.edu.co/handle/11190/1973
Citation: Gómez Gónzalez, J.M. y Mejía Mejía E. (2014) Sistema para la monitorización de la presión intraabdominal (Trabajo de grado). Recuperado de: http://repository.eia.edu.co/handle/11190/1973
Autorization: openAccess
Location: BIOM00235
Appears in Collections:Ingeniería Biomédica

Files in This Item:
File Description SizeFormat 
GomezJuan_2014_SistemaMonitorizacionPresion.pdfTrabajo de grado6.01 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.