Publicación: Simulation of a neonatal monitor for medical training purposes
dc.contributor.author | Cifuentes, Jenny A. | spa |
dc.contributor.author | Prieto-Ortiz, Flavio Augusto | spa |
dc.contributor.author | Méndez, Luis Carlos | spa |
dc.creator.email | [email protected] | spa |
dc.creator.email | [email protected] | spa |
dc.creator.email | [email protected] | spa |
dc.date.accepted | 2011-09-15 | spa |
dc.date.accessioned | 2013-11-14T13:42:57Z | spa |
dc.date.available | 2013-11-14T13:42:57Z | spa |
dc.date.created | 2011-12 | spa |
dc.date.issued | 2013-11-14 | spa |
dc.date.submitted | 2011-01-13 | spa |
dc.description | The design of a neonatal monitor for medical training purposes is hereby presented. In order to do that, the following main vital signs were modeled and simulated: ECG, pulse, blood pressure, CO2 level, among others. The signals were integrated to a graphic interface that generates different scenarios showing signals of patients with or without pathologies. Simulated signals were validated against real ones and, in general, the error is less than 5 %; in addition, the neonatal monitor was assessed by 16 specialists; those doctors stated that simulated signals are of “excellent quality”, “truthful” and that the interface is “user friendly”. | spa |
dc.description.abstract | Se presenta el desarrollo de un monitor neonatal orientado al entrenamiento médico. Para esto se modelaron y simularon los principales signos vitales como son: señal ECG, señal de pulso, presión arterial, nivel de CO2, entre otros. Las señales fueron integradas en una interfaz gráfica, la cual permite generar diferentes escenarios de pacientes, no solo normales sino también con patologías. Las señales simuladas fueron validadas contra señales reales y, en general, el error es inferior al 5 %. El monitor neonatal fue evaluado por 16 médicos especialistas quienes manifestaron que las señales simuladas son “de excelente calidad”, “fidedignas” y que la interfaz es “amigable al usuario”. | spa |
dc.format.extent | 19 p. | spa |
dc.format.mimetype | application/pdf | spa |
dc.identifier.bibliographiccitation | Cifuentes, J., Prieto, F., and Méndez, L. C. (2011), Simulation of a neonatal monitor for medical training purposes, Revista EIA, 8 (16), 9-27. doi: http://hdl.handle.net/11190/139 | spa |
dc.identifier.issn | ISSN 17941237 | spa |
dc.identifier.uri | https://repository.eia.edu.co/handle/11190/139 | spa |
dc.language.iso | eng | spa |
dc.publisher.editor | Fondo Editorial EIA | spa |
dc.relation.ispartof | Revista EIA | spa |
dc.relation.references | Ahrens, Thomas and Rutherford, Kim. Essentials of oxygenation: Implication for clinical practice. Boston: Jones and Bartlett, 1993. 40 p. | spa |
dc.relation.references | Alinier, Guillaume; Hunt, Barry; Gordon, Ray and Harwood, Colin (2006). “Effectiveness of intermediatefidelity simulation training technology in undergraduate nursing education”. Journal of Advanced Nursing, vol. 54, No. 3 (May), pp. 359-369. | spa |
dc.relation.references | Barash, Paul; Cullen, Bruce; Stoelting, Robert and Cahalan, Michael. Clinical anesthesia. 6th ed. Philadelphia: Lippincott Williams & Wilkins, 2009. | spa |
dc.relation.references | Beneken, William (1965). “A mathematical approach to cardiovascular function. The uncontrolled human system”. Ph. D. dissertation. Institute of Medical Physics. Utrecht, The Netherlands. | spa |
dc.relation.references | Bhavani-Shankar, K.; Moseley, H.; Kumar, A. Y. and Delph, Y. (1992). “Capnometry and anaesthesia”. Canadian Journal of Anaesthesia, vol. 39, No. 6 (July), pp. 617-632. | spa |
dc.rights | Derechos Reservados - Universidad EIA, 2020 | spa |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | spa |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | spa |
dc.rights.creativecommons | Atribución-NoComercial | spa |
dc.rights.license | El autor de la obra, actuando en nombre propio, hace entrega del ejemplar respectivo y de sus anexos en formato digital o electrónico y autoriza a la ESCUELA DE INGENIERIA DE ANTIOQUIA, para que en los términos establecidos en la Ley 23 de 1982, Ley 44 de 1993, Decisión andina 351 de 1993, Decreto 460 de 1995, y demás normas generales sobre la materia, utilice y use por cualquier medio conocido o por conocer, los derechos patrimoniales de reproducción, comunicación pública, transformación y distribución de la obra objeto del presente documento. PARÁGRAFO: La presente autorización se hace extensiva no sólo a las dependencias y derechos de uso sobre la obra en formato o soporte material, sino también para formato virtual, electrónico, digital, y en red, internet, extranet, intranet, etc., y en general en cualquier formato conocido o por conocer. EL AUTOR, manifiesta que la obra objeto de la presente autorización es original y la realiza sin violar o usurpar derechos de autor de terceros, por lo tanto la obra es de exclusiva autoría y tiene la titularidad sobre la misma. PARÁGRAFO: En caso de presentarse cualquier reclamación o acción por parte de un tercero en cuanto a los derechos de autor sobre la obra en cuestión, EL AUTOR, asumirá toda la responsabilidad, y saldrá en defensa de los derechos aquí autorizados; para todos los efectos la ESCUELA DE INGENIERÍA DE ANTIOQUIA actúa como un tercero de buena fe. | spa |
dc.rights.uri | https://creativecommons.org/licenses/by-nc/4.0/ | spa |
dc.subject.eia | TECNOLOGÍAS PARA LA SALUD | spa |
dc.subject.eurovoc | SIMULACIÓN | spa |
dc.subject.eurovoc | SIMULATION | spa |
dc.subject.keywords | MONITOR NEONATAL | spa |
dc.subject.keywords | VITAL SIGNS | spa |
dc.subject.keywords | MEDICAL TRAINING | spa |
dc.subject.keywords | SIGNAL MODELING | spa |
dc.subject.keywords | MONITOR NEONATAL | spa |
dc.subject.keywords | SIGNOS VITALES | spa |
dc.subject.keywords | ENTRENAMIENTO MÉDICO | spa |
dc.subject.keywords | MODELADO DE SEÑALES | spa |
dc.subject.lcsh | REI00158 | spa |
dc.title | Simulation of a neonatal monitor for medical training purposes | spa |
dc.title.alternative | Simulação de um monitor neonatal para treinamento médico | spa |
dc.title.alternative | Simulación de un monitor neonatal para entrenamiento médico | spa |
dc.type | Artículo de revista | spa |
dc.type.coar | http://purl.org/coar/resource_type/c_6501 | spa |
dc.type.coarversion | http://purl.org/coar/version/c_970fb48d4fbd8a85 | spa |
dc.type.content | Text | spa |
dc.type.driver | info:eu-repo/semantics/article | spa |
dc.type.redcol | https://purl.org/redcol/resource_type/ART | spa |
dc.type.version | info:eu-repo/semantics/publishedVersion | spa |
dspace.entity.type | Publication |