Examinando por Autor "García-Quiroz, F. (Felipe)"
Mostrando 1 - 8 de 8
Resultados por página
Opciones de ordenación
Publicación Acceso abierto La Biotecnología y el desarrollo de investigación aplicada en el programa de Ingeniería Biomédica de la EIA y el CES(2014-04-20) López-Rojas, L. E. (Luis Ernesto); García-Quiroz, F. (Felipe); Londoño-Peláez, C. (Carolina)Publicación Acceso abierto Desarrollo de un sistema de audición vibrotáctil para el acceso a la música: Fase I(2013-09-26) Villa-Moreno, A. (Adriana); García-Quiroz, F. (Felipe); Castaño-Jaramillo, P. (Paula); Londoño-Jaramillo, N. (Nathalia)The sense of touch transmits not only isolated tactile sensations also information that can be processed at the cerebral cortex in a similar way as it is in the brain areas for audition or vision. Both vibratile and electrical stimuli have been used for tactile stimulation devices, and the former was chosen for the system presented. The tactile auditory-substitution systems have focused on communication skills, but this work pretends the construction of a device for developing musical and artistic skills. These should be reflected in the capacity to identify musical pieces through tactile stimulation. The graphical user interface of the system was programmed using the virtual instrumentation software LabVIEW 7.0. It includes tools for the learning of the system, which were developed to help increasing the sensitivity of the user. Besides, to ensure a clear association with music theory and acoustic concepts some visual feedback systems were implementedPublicación Acceso abierto Development of a Dynamic Goniometer with an Incremental Encoder(2014-04-19) García-Quiroz, F. (Felipe); Villa-Moreno, A. (Adriana); Restrepo-Peláez, M. (María)La medición dinámica de los ángulos articulares se ha convertido en un parámetro fundamental para deportistas, médicos y analistas de los procesos de rehabilitación. El desarrollo de dispositivos para estas aplicaciones ha presentado retos importantes debido a la imposibilidad de implementar los sistemas mecánicos requeridos para la medición, sin afectar el movimiento natural de las articulaciones. Los goniómetros digitales se han construido a partir de diferentes principios electrónicos, particularmente basados en las variaciones resistivas de potenciómetros. Este trabajo muestra el desarrollo e implementación de un goniómetro dinámico basado en un encoder incremental con un sistema de transmisión mecánico entre una articulación de tipo bisagra y una polea conectada a un disco óptico. La rotación se detecta con un LED infrarrojo y un fototransistor. El cálculo del movimiento angular en la articulación se realiza con un microcontrolador. Finalmente los datos se muestran en tiempo real en una pantalla de cristal líquido (LCD).Publicación Acceso abierto Engineering antibody fragments: replicating the immune system and beyond(2014-04-24) García-Quiroz, F. (Felipe); Sinclair, M. (Michael)Las tecnologías para la ingeniería de anticuerpos han evolucionado durante las últimas dos décadas, desde la demostración de la posibilidad de humanizar anticuerpos monoclonales de ratón mediante ingeniería genética, apoyadas en el creciente entendimiento de los mecanismos involucrados en la generación de anticuerpos in vivo, y en una búsqueda constante de rutas alternativas para evolucionar y explotar sus características. Es así como los ingenieros de anticuerpos han desarrollado estrategias innovadoras para la evolución y selección de anticuerpos y de novedosos diseños de anticuerpos conocidos como fragmentos de anticuerpos. Esta revisión se enfoca en tres tecnologías que comprenden el núcleo de las tecnologías actualmente disponibles para el descubrimiento y preparación de tales anticuerpos: la presentación en fagos, la presentación en células, y la presentación en ribosomas. Este artículo busca presentar el estado del arte de estas tecnologías a un grupo general de lectores interesados en este campo, por lo que inicialmente se introducen importantes conceptos de inmunología requeridos para comprender en detalle las tecnologías discutidas. Una comparación de estas metodologías para la ingeniería de anticuerpos sugiere que a pesar del dominio de las tecnologías basadas en la presentación en fagos durante los últimos 20 años, en los próximos años la presentación en células y la presentación en ribosomas probablemente ganarán importancia para la selección y descubrimiento de fragmentos de anticuerpos. Finalmente, es probable que estas tecnologías jueguen un papel importante en la producción de la siguiente generación de terapéuticos basados en anticuerpos.Publicación Acceso abierto Interfaces neuronales y sistemas máquina-cerebro: fundamentos y aplicaciones. Revisión(2014-04-19) García-Quiroz, F. (Felipe); Villa-Moreno, A. (Adriana); Castaño-Jaramillo, P. (Paula)Abstract—During the past ten years the Neural Interfaces and brain-computer communication systems area has become an important field for research, in part due to the increasing statistics of motor and sensorial disabilities. The development of these systems and interfaces requires the coordinated work of different areas such as physiology, materials science, instrumentation and signal processing, computational intelligence, mechanics, electronics, robotics, and informatics, among others. They allowed the right integration between the nervous system physiology, the construction of biocompatible electrodes, the acquiring of proper signals for processing, the classification and identification of coded patterns and the design of the actuators elements to finally achieve the goal of the interface. In this review the three basic stages of neural interfaces are shown. This includes: signal acquiring, signal processing and the wide variety of applications with the effectors systems.Publicación Acceso abierto Isolation of human bone marrow mesenchymal stem cells and evaluation of their osteogenic potential(2014-04-23) García-Quiroz, F. (Felipe); Posada-Estefan, O. (Olga); Gallego Pérez, D. (Daniel); Higuita-Castro, N. (Natalia); Sarassa-Velásquez, C. (Carlos); Hansford, D. (Derek); Agudelo-Florez, P. (Piedad); López-Rojas, L. E. (Luis Ernesto)Human bone marrow mesenchymal stem cells (hBMSCs) comprise a cell population capable of self-renewal and multilineage differentiation commonly isolated from bone marrow aspirates of large bones. Their osteogenic potential has been extensively exploited for the biological evaluation of scaffolds or biomaterials with applications in bone tissue engineering. This work aimed to isolate hBMSCs from femoral heads of patients undergoing total hip arthroplasty and to evaluate their osteogenic potential. Briefly, the trabecular bone was extracted and mechanically disaggregated; the released cells were cultured and non-adherent cells were removed after 4 days. The osteogenic potential was evaluated at the fifth passage after 14 and 20 days of induction, comparing cultures with and without osteogenic supplements, via Alizarin red staining and the quantification of the gene expression levels of the osteogenic markers collagen type I, osteonectin and bone sialoprotein through real-time RT-PCR. The obtained hBMSCs presented a stable undifferentiated phenotype after prolonged cell culture, matrix mineralization capabilities and expression of osteoblast phenotype upon osteogenic induction. The three markers were up-regulated in cultures under osteogenic conditions and 2 fold differences in their expression levels were found to be significant for the onset of the differentiation process. The obtained hBMSCs may have applications on the in vitro evaluation of the osteoinductivity of different biomaterials, bioactive molecules or tissue engineering scaffolds.Publicación Acceso abierto Preguntas y respuestas sobre medicina regenerativa(2014-04-30) Zapata-Linares, N. (Natalia); García-Quiroz, F. (Felipe)Regenerative Medicine seeks to develop strategies to restore damaged tissues. The recent boom of this research fi eld and its potential for the treatment of a wide variety of diseases —such as neurodegenerative, hepatic and cardiac, or skin burns and various traumas— demands an ongoing analysis of the most recent investigations, their impact, the associated ethical debates, as well as the research horizon in the coming years. To answer these and other questions we reviewed the most important advances reported throughout the year 2011 and consulted the opinion of a regenerative medicine expert, profesor Felipe Prosper Cardoso from the University of Navarra in Spain. Despite the signifi cant progress in the laboratory regarding the derivation of autologous cells (whether differentiated or pluripotent) and the development of biomaterials that facilitate regeneration, the clinical translation of regenerative medicine therapies is still incipient and constitutes a grand challenge for researchers in this fascinating fieldPublicación Acceso abierto Reflexión: sostenibilidad y procesos de calidad en una revista científica latinoamericana(2014-04-23) García-Quiroz, F. (Felipe); Salazar-Gómez, A. (Andrés); Ramírez-Giraldo, J. C. (Juan Carlos); Londoño-Peláez, C. (Carolina)