Please use this identifier to cite or link to this item: http://repository.eia.edu.co/handle/11190/139
Full metadata record
DC FieldValueLanguage
dc.creatorCifuentes, Jenny A.-
dc.creatorPrieto-Ortiz, Flavio Augusto-
dc.creatorMéndez, Luis Carlos-
dc.date.accessioned2013-11-14T13:42:57Z-
dc.date.available2013-11-14T13:42:57Z-
dc.date.created2011-12-
dc.date.issued2013-11-14-
dc.date.submitted2011-01-13-
dc.identifier.urihttp://hdl.handle.net/11190/139-
dc.descriptionThe design of a neonatal monitor for medical training purposes is hereby presented. In order to do that, the following main vital signs were modeled and simulated: ECG, pulse, blood pressure, CO2 level, among others. The signals were integrated to a graphic interface that generates different scenarios showing signals of patients with or without pathologies. Simulated signals were validated against real ones and, in general, the error is less than 5 %; in addition, the neonatal monitor was assessed by 16 specialists; those doctors stated that simulated signals are of “excellent quality”, “truthful” and that the interface is “user friendly”.spa
dc.description.abstractSe presenta el desarrollo de un monitor neonatal orientado al entrenamiento médico. Para esto se modelaron y simularon los principales signos vitales como son: señal ECG, señal de pulso, presión arterial, nivel de CO2, entre otros. Las señales fueron integradas en una interfaz gráfica, la cual permite generar diferentes escenarios de pacientes, no solo normales sino también con patologías. Las señales simuladas fueron validadas contra señales reales y, en general, el error es inferior al 5 %. El monitor neonatal fue evaluado por 16 médicos especialistas quienes manifestaron que las señales simuladas son “de excelente calidad”, “fidedignas” y que la interfaz es “amigable al usuario”.spa
dc.format.extent19 p.spa
dc.format.mimetypeapplication/pdfspa
dc.language.isoenspa
dc.relation.ispartofRevista EIA-
dc.subject.lcshREI00158spa
dc.titleSimulation of a neonatal monitor for medical training purposesspa
dc.title.alternativeSimulación de un monitor neonatal para entrenamiento médicospa
dc.title.alternativeSimulação de um monitor neonatal para treinamento médico-
dc.typeArticlespa
dc.rights.accesRightsopenAccessspa
dc.creator.emailjacifuentesq@unal.edu.cospa
dc.creator.emailfaprietoo@unal.edu.cospa
dc.creator.emaillcmendezc@unal.edu.cospa
dc.date.accepted2011-09-15-
dc.identifier.bibliographicCitationCifuentes, J., Prieto, F., and Méndez, L. C. (2011), Simulation of a neonatal monitor for medical training purposes, Revista EIA, 8 (16), 9-27. doi: http://hdl.handle.net/11190/139spa
dc.identifier.idBiblioISSN 17941237spa
dc.publisher.editorFondo Editorial EIAspa
dc.relation.referencesAhrens, Thomas and Rutherford, Kim. Essentials of oxygenation: Implication for clinical practice. Boston: Jones and Bartlett, 1993. 40 p.spa
dc.relation.referencesAlinier, Guillaume; Hunt, Barry; Gordon, Ray and Harwood, Colin (2006). “Effectiveness of intermediatefidelity simulation training technology in undergraduate nursing education”. Journal of Advanced Nursing, vol. 54, No. 3 (May), pp. 359-369.spa
dc.relation.referencesBarash, Paul; Cullen, Bruce; Stoelting, Robert and Cahalan, Michael. Clinical anesthesia. 6th ed. Philadelphia: Lippincott Williams & Wilkins, 2009.spa
dc.relation.referencesBeneken, William (1965). “A mathematical approach to cardiovascular function. The uncontrolled human system”. Ph. D. dissertation. Institute of Medical Physics. Utrecht, The Netherlands.spa
dc.relation.referencesBhavani-Shankar, K.; Moseley, H.; Kumar, A. Y. and Delph, Y. (1992). “Capnometry and anaesthesia”. Canadian Journal of Anaesthesia, vol. 39, No. 6 (July), pp. 617-632.spa
dc.rights.licenseEl autor de la obra, actuando en nombre propio, hace entrega del ejemplar respectivo y de sus anexos en formato digital o electrónico y autoriza a la ESCUELA DE INGENIERIA DE ANTIOQUIA, para que en los términos establecidos en la Ley 23 de 1982, Ley 44 de 1993, Decisión andina 351 de 1993, Decreto 460 de 1995, y demás normas generales sobre la materia, utilice y use por cualquier medio conocido o por conocer, los derechos patrimoniales de reproducción, comunicación pública, transformación y distribución de la obra objeto del presente documento. PARÁGRAFO: La presente autorización se hace extensiva no sólo a las dependencias y derechos de uso sobre la obra en formato o soporte material, sino también para formato virtual, electrónico, digital, y en red, internet, extranet, intranet, etc., y en general en cualquier formato conocido o por conocer. EL AUTOR, manifiesta que la obra objeto de la presente autorización es original y la realiza sin violar o usurpar derechos de autor de terceros, por lo tanto la obra es de exclusiva autoría y tiene la titularidad sobre la misma. PARÁGRAFO: En caso de presentarse cualquier reclamación o acción por parte de un tercero en cuanto a los derechos de autor sobre la obra en cuestión, EL AUTOR, asumirá toda la responsabilidad, y saldrá en defensa de los derechos aquí autorizados; para todos los efectos la ESCUELA DE INGENIERÍA DE ANTIOQUIA actúa como un tercero de buena fe.spa
dc.subject.eiaTECNOLOGÍAS PARA LA SALUDspa
dc.subject.eurovocSIMULACIÓNspa
dc.subject.eurovocSIMULATIONspa
dc.subject.keywordsMONITOR NEONATALspa
dc.subject.keywordsVITAL SIGNSspa
dc.subject.keywordsMEDICAL TRAININGspa
dc.subject.keywordsSIGNAL MODELINGspa
dc.subject.keywordsMONITOR NEONATALspa
dc.subject.keywordsSIGNOS VITALESspa
dc.subject.keywordsENTRENAMIENTO MÉDICOspa
dc.subject.keywordsMODELADO DE SEÑALESspa
Appears in Collections:Revista EIA

Files in This Item:
File Description SizeFormat 
REI00158.pdf1.78 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.